| Honeywell HD660 Series · Model naming rules | ||
| Rank name | Example characters | Explanation of meaning |
| Series number | HD660 | Series Number: Honeywell Drives Universal Inverter Series Number |
| Power supply method | T | Power supply method: T = three-phase AC input; S = single-phase AC input; B = single-phase/three-phase AC input |
| Capacity | 0075 | capacity:0007=0.75kW;0075=7.5kW;0750=75kW;4500=450kW |
| Voltage level | B | Voltage level:A=220V(187V~253V); B=380V(323V~437V); C=440V(308V~484V) |
| Input-side filter | EMC | Input-side filter: EMC = with input-side filter; None = No input-side filter |
| DC reactors | DCR | With DC reactor: DCR = reactor with input; None = No input-side reactor |
| Custom version number | XX | Custom version number: XX = custom version number; None = Standard version |
| Honeywell HD660 Series Universal Inverter · Performance parameters | ||
| Category | Project name | Specifications |
| Basic control functions | Control methods | V/F control; Open-loop vector control |
| Highest frequency | Vector control: 0~320Hz; V/F control: 0~3200Hz | |
| Carrier frequency | 1kHz~16kHz; Carrier frequency can be automatically adjusted according to load characteristics; if it exceeds the factory default setting, please reduce capacity | |
| Input frequency resolution | Digital setting: 0.01Hz; Analog setting: Maximum frequency×0.025% | |
| Start torque | Constant torque application: 0.5Hz/150% (no PG); Square torque application: 0.5Hz/100% | |
| Speed control range | 1:100 (no PG) | |
| Steady speed accuracy | ± 0.5% (no PG) | |
| Overload capacity | Constant torque application: 150% rated current 60s; 180% rated current for 3 seconds. Square torque application: 120% rated current 60s; 150% rated current for 3 seconds | |
| Torque increase | Automatic torque increase; Manual torque increased by 0.1%~30.0% | |
| V/F curve | Three methods: linear type; Multi-point type; N-th power V/F curve | |
| V/F separation | Two methods: full separation and partial separation | |
| acceleration and deceleration curve | Straight-line or S-curve acceleration methods. Four acceleration and deceleration durations, with a range of 0.0~6500.0 seconds | |
| DC braking | DC braking frequency: 0.00Hz~maximum frequency; Braking time: 0.0s~100.0s; Braking action current value: 0.0%~100.0% | |
| Jog control | Jog frequency range: 0.00Hz~50.00Hz. Jog acceleration and deceleration time is 0.0s~6500.0s | |
| Simple PLC, multi-speed operation | Up to 16 speed levels can be achieved through built-in PLC or control terminals | |
| Built-in PID | It facilitates the implementation of closed-loop process control systems | |
| Automatic Voltage Regulation (AVR) | When the grid voltage changes, it can automatically maintain a constant output voltage | |
| Overvoltage, overcurrent, stall control | Automatically limits current and voltage during operation to prevent frequent overcurrent, overvoltage, and tripping | |
| Fast rate limiting function | Minimize overcurrent faults and protect the inverter for normal operation | |
| Torque limiting and control | The "excavator" features automatically limit torque during operation to prevent frequent overcurrent, overvoltage, and tripping trips | |
| Personalized features | Outstanding performance | Achieves asynchronous motor control using high-performance current vectoring technology |
| Stopping in an instant | During a momentary power outage, the load compensates for the drop in voltage by feeding back energy, keeping the inverter running for a short period | |
| Rapid rate limiting | This helps prevent frequent overcurrent faults in the frequency converter | |
| Timing control | Timer control function: set time range 0.0 min ~ 6500 0 min | |
| Communication methods are supported | RS-485 | |
| Run | Run the command channel | Keyboard set, control terminal set, serial communication port set. It can be switched in multiple ways |
| Frequency source | 10 frequency sources: digital setpoint, analog voltage setpoint, analog current setpoint, pulse setpoint, serial port setpoint. It can be switched in multiple ways | |
| Auxiliary frequency source | 10 types of auxiliary frequency sources. Flexible auxiliary frequency fine-tuning and frequency synthesis can be achieved | |
| Input terminal | Standard: 6 digital input terminals, including 1 supporting high-speed pulse input up to 100kHz (optional); Two analog input terminals, one supports only 0~10V voltage input; One supports 0~10V voltage input or 4~20mA current input | |
| Output terminals | 1 digital output terminal; 1 relay output terminal; One analog output terminal supports 0~20mA current output or 0~10V voltage output | |
| Keyboard operation | LED display | Display parameters |
| Key locking and function selection | Lock part or all of the keys, defining the range of function of some keys to prevent accidental operation | |
| Protection function | Upper motor short circuit detection, output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, etc | |
| Environment | Usage Locations | Indoors, it should not be exposed to direct sunlight, nor dust, corrosive gases, flammable gases, oil mist, water vapor, dripping water, or salt |
| Elevation | Below 1000m (above 1000m, downshift required) | |
| Ambient temperature | -20°C~+50°C (For ambient temperatures above 50°C, please reduce capacity before use) | |
| Humidity | Less than 95% RH, no water droplet condensation | |
| Vibration | Less than 5.9m/s² (0.6g) | |
| Storage temperature | -40℃~+70℃ | |
| Certification | Certification | CE certification |

Techenn supplies VFD, motors, and electrical components, and manufactures custom non-standard automation control cabinets in our own factory. We also deliver electrical and automation solutions across manufacturing, energy & power, petrochemical, metallurgy & mining, and infrastructure — supporting both domestic and overseas projects.