Fin du contenu.
Fin du contenu.
| Variateur vectoriel polyvalent de la série NZ200 | |
| Product features | |
| • | Open-loop vector control, V/F control |
| • | Strong overload capacity: 150% rated current per 60s and 180% rated current per 3s |
| • | Superior performance and good environmental adaptability |
| • | Simple structure, compact size, and easy installation |
| • | General-purpose vector frequency converter with high torque output ensures smooth motor start under heavy load |
| • | It features instantaneous stop and rapid current limiting functions, reducing the frequency converter's frequent fault alarms |
| • | Comprehensive protection functions include output phase loss protection, overcurrent/overvoltage/overload/overheat protection, among others |
| • | Supports permanent magnet synchronous motor control (NZ200T series) |
| Power range | |
| 220V | 0.4~3.7kW (5.5kW and above can be specially ordered) |
| 380V | 0.4~630kW |
| Classification | Project name | Specifications |
| Basic functions | Control methods | V/F control; Open-loop vector control (no PG) |
| Highest frequency | Vector control: 0~320Hz; V/F control: 0~320Hz | |
| Carrier frequency | 1kHz~16kHz, carrier frequency can be automatically adjusted according to load characteristics | |
| Input frequency resolution | Digital setting: 0.01Hz; Analog setting: Maximum frequency×0.025% | |
| Start torque | G model: 0.5Hz/150% (no PG); P model: 0.5Hz/100% | |
| Speed control range | 1:100 (no PG) | |
| Steady speed accuracy | ± 0.5% (no PG) | |
| Overload capacity | G model: 150% rated current 60s, 180% rated current 3s; P-type machine: 120% rated current 60s, 150% rated current 3s | |
| Torque increase | Automatic torque increase; Manual torque increased by 0.1%~30.0% | |
| V/F curve | Three methods: linear type; Multi-point type; N-th Power V/F Curve (1.2, 1.4, 1.6, 1.8, 2 powers) | |
| V/F separation | Two methods: full separation and partial separation | |
| acceleration and deceleration curve | Linear or S-curve acceleration and deceleration methods, four acceleration and deceleration durations, with a time range of 0.0~6500.0 seconds | |
| DC braking | Braking frequency: 0.00Hz~maximum frequency; Braking time: 0.0s~100.0s; Braking action current value: 0.0%~100.0% | |
| Jog control | Jog frequency range: 0.00Hz~50.00Hz; Jogging acceleration and deceleration time: 0.0s~6500.0s | |
| Simple PLC, multi-speed operation | Up to 16 speed levels can be achieved through built-in PLC or control terminals | |
| Built-in PID | It facilitates the implementation of closed-loop process control systems | |
| Automatic Voltage Regulation (AVR) | When the grid voltage changes, it can automatically maintain a constant output voltage | |
| Personalized features | Overvoltage, overcurrent, stall control | Automatically limits current and voltage during operation to prevent frequent overcurrent, overvoltage, and tripping |
| Fast rate limiting function | Minimize overcurrent faults and protect the inverter for normal operation | |
| Torque limiting and control | The "excavator" features automatic torque limitation during operation to prevent frequent overcurrent trips | |
| Outstanding performance | Achieves asynchronous motor control using high-performance current vectoring technology | |
| Stopping in an instant | During a momentary power outage, the load returns energy to compensate for the voltage drop, keeping the inverter running for a short time | |
| Rapid rate limiting | Avoid frequent overcurrent faults | |
| Timing control | Timer control function, set time range 0.0 min ~ 6500.0 min | |
| Communication methods | RS485 | |
| Run the command channel | Keyboard setting, control terminal setting, and serial communication port can be switched in various ways | |
| Frequency source | 10 frequency sources: digital set, analog voltage setpoint, analog current setpoint, pulse setpoint, and serial port setpoint, with multiple switching options | |
| Auxiliary frequency source | 10 auxiliary frequency sources for flexible auxiliary frequency fine-tuning and frequency synthesis | |
| Run | Input terminal | 6 digital input terminals, 1 supporting up to 100kHz high-speed pulse input (S3 optional); Two analog input terminals: one supports only 0~10V voltage input (FIV), and one supports 0~10V voltage input or 4~20mA current input (FIC) |
| Output terminals | 1 digital output terminal (MO1); 1 relay output terminal (R0A, R0B, R0C); 1 analog output terminal, supports 0~20mA current output or 0~10V voltage output (FOV) | |
| Note | The default X terminal is NPN type; if PNP type is needed, customization is required | |
| Keyboard operation and display | LED display | Display parameters |
| Key locking and function selection | Locks part or all of the buttons, defines the range of certain buttons, and prevents accidental operation | |
| Protection function | Short-circuit detection of power-on motors, output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheating protection, overload protection, etc | |
| Environment | Usage Locations | Indoors, avoid direct sunlight, and be free of dust, corrosive gases, flammable gases, oil mist, water vapor, dripping water, or salt |
| Elevation | Below 1000m (above 1000m, downshift is required) | |
| Ambient temperature | -10°C~+40°C (please downshift when ambient temperature is 40°C~50°C) | |
| Humidity | 5%~95% RH, no water droplet condensation | |
| Vibration | Less than 5.9m/s² (0.6g) | |
| Storage temperature | -20℃~+60℃ | |
| Structure | Cooling method | Forced air cooling |
| Protection rating | IP20 | |
| Note: For specific functions of each power band, please refer to the basic wiring diagram | ||
| Inverter model | Input current (A) | Output power (kW) | Capacity (KVA) | Output current (A) | Overload Capacity (60s) (A) | Applicable Motors (kW) |
| Input voltage: 1PH AC220V ±15% | ||||||
| NZ200-0R4G-2 | 5.4 | 0.4 | 1 | 2.5 | 3.75 | 0.4 |
| NZ200-0R75G-2 | 7.2 | 0.75 | 2 | 5 | 7.5 | 0.75 |
| NZ200-1R5G-2 | 10 | 1.5 | 2.8 | 7 | 10.5 | 1.5 |
| NZ200-2R2G-2 | 16 | 2.2 | 4.5 | 11 | 16.5 | 2.2 |
| NZ200-3R7G-2 | 17 | 3.7 | 7.2 | 16.5 | 24.75 | 3.7 |
| Input voltage: 3PH AC380V ±15% | ||||||
| NZ200-0R4G-4 | 3.4 | 0.4 | 2.2 | 1.2 | 1.8 | 0.4 |
| NZ200-0R75G-4 | 3.8 | 0.75 | 2.2 | 2.5 | 3.75 | 0.75 |
| NZ200-1R5G-4 | 5 | 1.5 | 3.2 | 3.7 | 5.55 | 1.5 |
| NZ200-2R2G-4 | 5.8 | 2.2 | 4 | 5 | 7.5 | 2.2 |
| NZ200-3R7G/5R5P-4 | 10.7 | 3.7 | 6.8 | 9 | 13.5 | 3.7 |
| NZ200-5R5G/7R5P-4 | 14.6 | 5.5 | 10 | 13 | 19.5 | 5.5 |
| NZ200-7R5G/11P-4 | 20 | 7.5 | 11.2 | 17 | 25.5 | 7.5 |
| NZ200-11G/15P-4 | 26 | 11 | 17 | 25 | 37.5 | 11 |
| NZ200-15G/18P-4 | 35 | 15 | 26 | 32 | 48 | 15 |
| NZ200-18G/22P-4 | 38 | 18.5 | 32 | 37 | 55.5 | 18.5 |
| NZ200-22G/30P-4 | 46 | 22 | 37 | 45 | 67.5 | 22 |
| NZ200-30G/37P-4 | 62 | 30 | 52 | 60 | 90 | 30 |
| NZ200-37G/45P-4 | 76 | 37 | 64 | 75 | 112.5 | 37 |
| NZ200-45G/55P-4 | 92 | 45 | 72 | 90 | 135 | 45 |
| NZ200-55G/75P-4 | 113 | 55 | 84 | 110 | 165 | 55 |
| NZ200-75G/90P-4 | 157 | 75 | 115 | 150 | 225 | 75 |
| NZ200-90G/110P-4 | 180 | 90 | 135 | 176 | 264 | 90 |
| NZ200-110G/132P-4 | 214 | 110 | 160 | 210 | 315 | 110 |
| NZ200-132G/160P-4 | 256 | 132 | 193 | 253 | 379.5 | 132 |
| NZ200-160G/185P-4 | 307 | 160 | 230 | 300 | 450 | 160 |
| NZ200-185G/200P-4 | 355 | 185 | 260 | 340 | 510 | 185 |
| NZ200-200G/220P-4 | 385 | 200 | 290 | 380 | 570 | 200 |
| NZ200-220G/250P-4 | 430 | 220 | 320 | 420 | 630 | 220 |
| NZ200-250G/280P-4 | 475 | 250 | 365 | 470 | 705 | 250 |
| NZ200-280G/315P-4 | 525 | 280 | 427 | 520 | 780 | 280 |
| NZ200-315G/350P-4 | 610 | 315 | 460 | 600 | 900 | 315 |
| NZ200-350G/400P-4 | 620 | 350 | 516 | 640 | 960 | 350 |
| NZ200-400G/450P-4 | 670 | 400 | 600 | 690 | 1035 | 400 |
| NZ200-450G/500P-4 | 790 | 450 | 638 | 790 | 1185 | 450 |
| NZ200-500G/560P | 865 | 500 | 725 | 860 | 1290 | 500 |
| NZ200-560G/630P | 960 | 560 | 812 | 950 | 1425 | 560 |
| NZ200-630G/710P | 1112 | 630 | 913 | 1100 | 1650 | 630 |
| Note: The 55G/630G cannot be combined with G/P, please note when ordering. | ||||||

Techenn fournit des variateurs de fréquence, des moteurs et des composants électriques, et fabrique dans sa propre usine des armoires de commande d'automatisation sur mesure et hors normes. Nous proposons également des solutions électriques et d'automatisation dans les secteurs de l'industrie manufacturière, de l'énergie et de l'électricité, de la pétrochimie, de la métallurgie et des mines, ainsi que des infrastructures, et accompagnons des projets tant en France qu'à l'international.