| Variateur vectoriel à usage général de la série NT200 | |
| Control methods | Open-loop vector control, V/F control |
| Overload capacity | Strong overload capacity: 150% rated current per 60s and 180% rated current per 3s |
| Product performance | Superior performance and good environmental adaptability |
| Structural features | Simple structure, compact size, and easy installation |
| Startup performance | General-purpose vector frequency converter with high torque output ensures smooth motor start under heavy load |
| Protection function | It features instantaneous stops and rapid current limiting functions, reducing the frequency converter's frequent fault alarms |
| Comprehensive protection | Comprehensive protection functions include output phase loss protection, overcurrent/overvoltage/overload/overheat protection, among others |
| Motor compatibility | Supports permanent magnet synchronous motor control (NT200T series) |
| Power range | 220V: 0.4-3.7kW (above 5.5L can be specially ordered); 380V: 0.4~315kW |
| NT200 Series General-Purpose Vector Inverter · Technical Specifications | ||
| Catégorie | Project name | Specifications |
| Basic functions | Control methods | V/F control; Open-loop vector control (no PG) |
| Highest frequency | Vector control: 0~320Hz; V/F control: 0~3200Hz | |
| Carrier frequency | 1kHz~16kHz; It can automatically adjust the carrier frequency according to load characteristics | |
| Input frequency resolution | Digital setting: 0.01Hz; Analog setting: Maximum frequency×0.025% | |
| Start torque | G model: 0.5Hz/150% (no PG); P model: 0.5Hz/100% | |
| Speed control range | 1:100 (no PG) | |
| Steady speed accuracy | ± 0.5% (no PG) | |
| Overload capacity | G-type machine: 150% rated current 60s; 180% rated current for 3 seconds. P-type machine: 120% rated current 60s; 150% rated current for 3 seconds | |
| Torque increase | Automatic torque increase; Manual torque increased by 0.1%~30.0% | |
| V/F curve | Three methods: linear type; Multi-point type; N-th Power V/F Curve (1.2, 1.4, 1.6, 1.8, 2) | |
| V/F separation | Two methods: full separation and partial separation | |
| acceleration and deceleration curve | Straight-line or S-curve acceleration and deceleration methods. Four acceleration and deceleration durations, with a range of 0.0~6500.0 seconds | |
| DC braking | DC braking frequency: 0.00Hz~maximum frequency; Braking time: 0.0s~100.0s; Braking action current value: 0.0%~100.0% | |
| Jog control | Jog frequency range: 0.00Hz~50.00Hz. Jog acceleration and deceleration time is 0.0s~6500.0s | |
| Simple PLC, multi-speed operation | Up to 16 speed levels can be achieved through built-in PLC or control terminals | |
| Built-in PID | It facilitates the implementation of closed-loop process control systems | |
| Automatic Voltage Regulation (AVR) | When the grid voltage changes, it can automatically maintain a constant output voltage | |
| Overvoltage, overcurrent, stall control | Automatically limits current and voltage during operation to prevent frequent overcurrent, overvoltage, and tripping | |
| Fast rate limiting function | Minimize overcurrent faults and protect the inverter for normal operation | |
| Torque limiting and control | The "excavator" features automatic torque limitation during operation to prevent frequent overcurrent trips | |
| Personalized features | Outstanding performance | Achieves asynchronous motor control using high-performance current vectoring technology |
| Stopping in an instant | During a momentary power outage, the load compensates for the drop in voltage by feeding back energy, keeping the inverter running for a short period | |
| Rapid rate limiting | This helps prevent frequent overcurrent faults in the frequency converter | |
| Timing control | Timer control function: set time range 0.0 min ~ 6500 0 min | |
| Communication methods are supported | RS-485 | |
| Run the command channel | Keyboard set, control terminal set, serial communication port set. It can be switched in multiple ways | |
| Run | Frequency source | 10 frequency sources: digital setpoint, analog voltage setpoint, analog current setpoint, pulse setpoint, serial port setpoint. It can be switched in multiple ways |
| Auxiliary frequency source | 10 types of auxiliary frequency sources. Flexible auxiliary frequency fine-tuning and frequency synthesis can be achieved | |
| Input terminal | Standard: 6 digital input terminals, including 1 supporting high-speed pulse input up to 100kHz (S3 optional); Two analog input terminals: one supports only 0~10V voltage input (FIV), and one supports 0~10V voltage input or 4~20mA current input (FIC) | |
| Output terminals | 1 digital output terminal (MO1); 1 relay output terminal (RA, RB, RC); 1 analog output terminal, supports 0~20mA current output or 0~10V voltage output (FOV) | |
| Note | The X terminal defaults to NPN type; if PNP type is required, customization is required | |
| Display and keyboard operation | LED display | Display parameters |
| Key locking and function selection | Lock part or all of the keys, defining the range of function of some keys to prevent accidental operation | |
| Protection function | Short-circuit detection of power-on motors, output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheating protection, overload protection, etc | |
| Environment | Usage Locations | Indoors, it should not be exposed to direct sunlight, nor dust, corrosive gases, flammable gases, oil mist, water vapor, dripping water, or salt |
| Elevation | Below 1000m (above 1000m, downshift required) | |
| Ambient temperature | -10°C~+40°C (ambient temperature is 40°C~50°C, please downgrade) | |
| Humidity | Less than 95% RH, no water droplet condensation | |
| Vibration | Less than 5.9m/s² (0.6g) | |
| Storage temperature | -20℃~+60℃ | |
| Note: For specific functions of each power band, please refer to the basic wiring diagram | ||
| NT200 Series · Specifications and models | ||||||
| Inverter model | Input current (A) | Output power (kW) | Capacity (KVA) | Output current (A) | Overload Capacity (60s) (A) | Applicable Motors (kW) |
| Input voltage: 1PH AC220V±15% | ||||||
| NT200-0R4G-2 | 5.4 | 0.4 | 1 | 2.5 | 3.75 | 0.4 |
| NT200-0R75G-2 | 7.2 | 0.75 | 2 | 5 | 7.5 | 0.75 |
| NT200-1R5G-2 | 10 | 1.5 | 2.8 | 7 | 10.5 | 1.5 |
| NT200-2R2G-2 | 16 | 2.2 | 4.5 | 11 | 16.5 | 2.2 |
| NT200-3R7G-2 | 17 | 3.7 | 7.2 | 16.5 | 24.75 | 3.7 |
| Input voltage: 3PH AC380V±15% | ||||||
| NT200-0R4G-4 | 3.4 | 0.4 | 2 | 1.2 | 1.8 | 0.4 |
| NT200-0R75G-4 | 3.8 | 0.75 | 2.2 | 2.5 | 3.75 | 0.75 |
| NT200-1R5G-4 | 5 | 1.5 | 3.2 | 3.7 | 5.55 | 1.5 |
| NT200-2R2G-4 | 5.8 | 2.2 | 4 | 5 | 7.5 | 2.2 |
| NT200-3R7G/5R5P-4 | 10.7 | 3.7 | 6.8 | 9 | 13.5 | 3.7 |
| NT200-5R5G/7R5P-4 | 14.6 | 5.5 | 10 | 13 | 19.5 | 5.5 |
| NT200-7R5G/11P-4 | 20 | 7.5 | 11.2 | 17 | 25.5 | 7.5 |
| NT200-11G/15P-4 | 26 | 11 | 17 | 25 | 37.5 | 11 |
| NT200-15G/18P-4 | 35 | 15 | 26 | 32 | 48 | 15 |
| NT200-18G/22P-4 | 38 | 18.5 | 32 | 37 | 55.5 | 18.5 |
| NT200-22G/30P-4 | 46 | 22 | 37 | 45 | 67.5 | 22 |
| NT200-30G/37P-4 | 62 | 30 | 52 | 60 | 90 | 30 |
| NT200-37G/45P-4 | 76 | 37 | 64 | 75 | 112.5 | 37 |
| NT200-45G/55P-4 | 92 | 45 | 72 | 90 | 135 | 45 |
| NT200-55G/75P-4 | 113 | 55 | 84 | 110 | 165 | 55 |
| NT200-75G/90P-4 | 157 | 75 | 115 | 150 | 225 | 75 |
| NT200-90G/110P-4 | 180 | 90 | 135 | 176 | 264 | 90 |
| NT200-110G/132P-4 | 214 | 110 | 160 | 210 | 315 | 110 |
| NT200-132G/160P-4 | 256 | 132 | 193 | 253 | 379.5 | 132 |
| NT200-160G/185P-4 | 307 | 160 | 230 | 300 | 450 | 160 |
| NT200-185G/200P-4 | 355 | 185 | 260 | 340 | 510 | 185 |
| NT200-200G/220P-4 | 385 | 200 | 290 | 380 | 570 | 200 |
| NT200-220G/250P-4 | 430 | 220 | 320 | 420 | 630 | 220 |
| NT200-250G/280P-4 | 475 | 250 | 365 | 470 | 705 | 250 |
| NT200-280G/315P-4 | 525 | 280 | 427 | 520 | 780 | 280 |
| NT200-315G/350P-4 | 610 | 315 | 460 | 600 | 900 | 315 |

Techenn fournit des variateurs de fréquence, des moteurs et des composants électriques, et fabrique dans sa propre usine des armoires de commande d'automatisation sur mesure et hors normes. Nous proposons également des solutions électriques et d'automatisation dans les secteurs de l'industrie manufacturière, de l'énergie et de l'électricité, de la pétrochimie, de la métallurgie et des mines, ainsi que des infrastructures, et accompagnons des projets tant en France qu'à l'international.